-30 to 900°C
(-25 to 1600 °F)
0.1°C of reading up to 900°C
0.2°F of reading up to 999.8°F
- D:S (Distance to spot size)
60:1 Standard focus
50:1 Close focus
- Minimum measurement diameter
19mm (0.76 in) Standard focus
6mm (0.24 in) Close focus
- Laser sighting Three point coaxial laser
- Emissivity Digitally adjustable from 0.10 to 1.0 by 0.01
- Display Accuracy [Assumes ambient operating temperature of 23°C(73°F) to 25°C(77°F)]
±0.75% of reading
±1% of reading or ±0.75°C (±1.5°F), whichever is greater
- Response time 250 mSec (95% of reading)
- Repeatability ±0.5% of reading or ±1°C (±2°F), whichever is greater
- Spectral response 8 µm to 14 µm
- Laser Sighting Laser turns off above ambient temperature of 40°C (104°F)
- Laser Power Class 2(II) operation; Output < 1mW, wavelength 630-670 nm
- Relative humidity 10% to 90% RH non-condensing, at < 30°C (86°F)
- Tripod mount ¼ in. 20 UNC threading
- Power 2 AA batteries/ AC adapter
- Battery life (alkaline) 13 hours with laser and backlight on 50%
- Display hold 7 seconds
- LCD backlit Yes
- Warranty 1 years
- Operating temperature
0°C to 50°C
32°F to 120°F
-20°C to 50°C
-25°F to 120°F
- MAX, MIN temperatures Yes
- DIF, AVG temperatures Yes
- Audible and visible alarms High and low
- Bar graph display Yes
- Up to 100 points data logging Data only
- Data graphing and storage software (Windows compatible) Data only
- Includes:
Durable hard case
Thermocouple K probe
Power supply
RS232 data cable
Data graphing, storage, and analysis software
2 AA batteries
- Manufacturer: Fluke - USA
- Made in CHINA